Clinical measurement of muscle tone using a velocity-corrected modified Ashworth scale

A. W. SMITH, M. JAMSHIDI, Sing Kai LO

Research output: Contribution to journalArticlespeer-review

28 Citations (Scopus)

Abstract

Objective: To develop a new form of the modified Ashworth scale (MAS) for muscle-tone assessment that combines the MAS score with the passive muscle-stretching velocity during the assessment of muscle tone, resulting in a measure that has higher intertester reliability than the MAS. 
Design: Twenty-two volunteer subjects with spinal cord injuries at a tertiary care outpatient and inpatient spinal cord injury rehabilitation center affiliated with a university were recruited for this study. 
Results: A decision tree in which V-MAS scores were obtained was developed. The data obtained from three independent raters, when adjusted by means of the V-MAS, showed an excellent interrater reliability. 
Conclusions: Results indicated that the V-MAS is a more reliable measure. In addition, the resulting units of the V-MAS, ranging from 0 to 1, are of the same form as pendulum test data. The V-MAS method is quite simple to use because the rater need only measure the angular range and duration of the passive movement to calculate average velocity during the MAS assessment in addition to the normal MAS rating of muscle tone. Copyright © 2002 Lippincott Williams & Wilkins, Inc.
Original languageEnglish
Pages (from-to)202-206
JournalAmerican Journal of Physical Medicine and Rehabilitation
Volume81
Issue number3
DOIs
Publication statusPublished - 2002

Citation

Smith, A. W., Jamshidi, M., & Lo, S. K. (2002). Clinical measurement of muscle tone using a velocity-corrected modified Ashworth scale. American Journal of Physical Medicine & Rehabilitation, 81(3), 202-206. doi: 10.1097/00002060-200203000-00008